Carrier Air Conditioner Fan Not Working

Contents

You can take the fan motor and capacitor to the nearest U-FIX-IT for free testing.JimReply Liam says: September 21, 2016 at 5:27 amThanks for posting this. HELP Cre8tor2 months ago from Ohio Author Thank you Greg. Does this mean now that I have to replace the fan motor?Reply Jim Plummer says: August 15, 2016 at 12:34 pmManny,If the capacitor is good and 220 volt power is present Cre8tor3 months ago from Ohio Author Jay - (and many others who've asked the same question) The "stick trick" is just a diagnosis tool so to speak. Source

Now in the bag which is a cover, there could be thermal device. If it was my unit I would start with replacing the fan motor and capacitor.JimReply Orion says: September 19, 2016 at 7:31 pmJim,Thanks for the response. I checked them incoming to the box. That would be an additional $334.00 for the tech to do.

Ac Unit Fan Not Spinning

The tech then recognized that the fan blades where on backwards (his fault). So unless you turn off the furnace power too, that 24v line is still hot. Loading...

Vic "Vita brevis" 07-27-12,03:18 PM #6 encino50 Member Join Date Jul 2012 State VA Posts 25 For sure! Noticed 3/8/2015 3/8/2015 alumalite I have a 5 ton carrier a/c unit, model 24abc660a300 on my residence. 8/4/2013 8/4/2013 alumalite Just had a field report on 7 year old Carrier. Capacitors can show signs of fatigue but usually when they go, they go.As for the comment regarding the low voltage...there is a slim chance of popping a fuse on the low Ac Fan Capacitor Cre8tor3 months ago from Ohio Author Paul Otnes - Thanks for reading and taking the time to comment.

Then check-out our page - heat pump iced-up in summer. (Even if it's not a heat pump.) Some equipment still use belt driven motors. Ac Compressor Not Running My AC unit is 18 years old, and I was afraid it was hopeless, but I decided to run through your checklist, and I was able to get it cleaned up Many technicians install hard starts on units located in rural areas or areas where electric power may fluctuate.

This was exactly what was wrong and was an easy fix.

Should make pointer deflect, swap leads on meter. Ac Fan Not Working In Car Getting awfully hot upstairs around here! The bottom four causes in blue are commonly found problems and can be addressed, even fixed by the homeowner. Jon4 months ago Great article.

Ac Compressor Not Running

The small amount of money you spend on an annual tune-up will pay off big-time in the future by avoiding potentially expensive fan repairs.If you have any questions about your central If the capacitor does not fix the problem, I would replace the motor and the capacitor. Ac Unit Fan Not Spinning Again thank you so much for taking the time to post!! Ac Inside Fan Not Working Which air conditioner, heat pump, or furnace fan is located where?

To those who've just bought something and are having issues, please, return it to the store before long so they can give you back your money or a new unit. this contact form Condenser fan runs but only intermittently and has trouble starting Check for loose wires or loose components on the fan unit control circuit board. Finally, someone to help those who don't understand this stuff. Wstinghouse wak087y7v1 KimG5 months ago I never leave reviews, but I seriously cannot thank you enough for this information!!!Your pictures are so useful and you helped me fix the problem!!!First time Why Is My Ac Outside Unit Not Turning On

I think I saw a bulge in the top of the capacitor when I had the panel off, but I would think that that would kill the fan, too, no? As it's Sunday, I couldn't find a place to buy a new capacitor. Even so, you might try sending your letter to a number of the service tech companies in your area and see what their response is. have a peek here Same thing yesterday.

But to save yourself a bunch of testing, we need to know if you are getting thermostat voltage to the outside unit, and we need to know, even though you replaced Ac Unit Fan Motor Then they put the compressor on common and to another terminal. Then I study the system until I am confident how the system is supposed to operate.If the problem has not presented itself during the above process, I would call the factory

With the power on, the voltage heading into the contactor (I think it's called?) read 240V so I'm getting good power to the contactor.

Choosing a Replacement There are a couple of things you'll want to know when shopping for your new capacitor: the micro-farads (μF) and the voltage rating. I measured between them and got 0.Fuses are fine (re-checked again) and the contactor has 240V. You don't want those to be touching the frame from bad insulation inside the motor. Central Air Conditioner Fan Not Spinning Thank you! :-) michael5 months ago Thank you so much!

Todd16 months ago My outside compressor unit is throwing the circuit breaker. I never reuse a capacitor that has been connected to a bad motor regardless of how short a time power was applied. Mechanical stoppage or resistance: Check for a mechanical obstruction (see photo at page top of a stick in the condensing fan) or for a fan bearing that is worn, sticking, freezing. Check This Out For those who are getting "dead air", if the outdoor unit is running then the best thing to do is check the filter and make sure it's not dirty.

For last couple of days it is operating normally. David2 months ago So my unit has been acting up and it wouldn't shut off. Gently slide the stick through the fan grate and give one of the fan blades a gentle push, to see if the fan will spin. As a matter of fact it now is almost impossible to turn with a stick, unlike before.

My system was low last year, serviced, and I'm wondering if it could be related/low again. Well, before you call the local HVAC technician to come fix the unit, and re-allocate the money you were going to spend on burgers, take a quick look.